MeasureMixNourish
Indications for Use
The Q-NRG+ portable Metabolic Monitors are indicated for the measurement of Resting Energy Expenditure (REE) for spontaneously breathing and ventilated patients, within the following populations:
- Spontaneously breathing subjects >15 kg (33 lb) when using a canopy.
- Spontaneously breathing subjects age >6 yrs and >10 kg (22 lb) when using a face mask.
- Ventilated subjects age >10 yrs and >10 kg (22 lb).
Q-NRG+ Portable Metabolic Monitors are intended to be used in professional healthcare facilities only (limited to ICUs for ventilated patients). Please read the accompanying full Indication(s) and Safety Information for Q-NRG+.
Experience the Q-NRG+ Virtual 360 Demo
Learn how Q-NRG+ enables individualized resting energy expenditure measurements at the point of care.
This tool is best viewed on desktop or in landscape mode on mobile.
US-CN21-210031 V2.0 6/22
MEASURE ACCURATELY
• Energy needs in critically ill patients are dynamic.1,2
• Predictive equations are inaccurate up to 50% of the time.3
• ASPEN Guidelines recommend using IC to accurately measure REE.4
• Maximizing protein while meeting calorie targets, guided by IC, can be important to critically ill patients.2
Why estimate when you can measure?
Request a Demo
MEASURE ACCURATELY
• Energy needs in critically ill patients are dynamic.1,2
• Predictive equations are inaccurate up to 50% of the time.3
• ASPEN Guidelines recommend using IC to accurately measure REE.4
• Maximizing protein while meeting calorie targets, guided by IC, can be important to critically ill patients.2
Why estimate when you can measure?
Request a Demo
MEASURE ACCURATELY
• Energy needs in critically ill patients are dynamic.1,2
• Predictive equations are inaccurate up to 50% of the time.3
• ASPEN Guidelines recommend using IC to accurately measure REE.4
• Maximizing protein while meeting calorie targets, guided by IC, can be important to critically ill patients.2
Why estimate when you can measure?
Request a Demo
Measure With Next Generation IC Technology
FAST
- ~10-15 minutes to run test (including warm-up time)5
- Minimal calibration time5
ACCURATE
- REE +/- 3% or 36 kcal/day, whichever is greater5
- Range (0-7200 kcal/day)5, tested vs. Mass Spectrometry6
INTUITIVE
- Real-time, user-friendly dashboard5
- Downloadable data in PDF or spreadsheet format5
- Lightweight (~10 lbs.), easily transported between rooms5
- Portable, battery powered5
- Ability to test on ventilated or spontaneously breathing patients5
Designed by Clinicians for Clinicians
Q-NRG+ is a standalone indirect calorimeter for measuring REE in both ventilated and spontaneously breathing patients. Q-NRG+ was designed with the International Multicentric Study for Indirect Calorimetry (ICALIC).7
The goal: develop a new IC device that addresses barriers according to the needs of the clinician.
The conclusion: ICALIC partnered with industry professionals to design the next generation IC technology that is accurate, reliable and easy-to-use.7
Explore Products for Individualized Clinical Nutrition
Clinimix (amino acids in dextrose) Injections
- Learn More
Clinolipid 20% (Lipid Injectable Emulsion) for intravenous use
- Learn More
Infuvite Multivitamins for Infusion
- Learn More
Amino Acid Injections
- Learn More
Q-NRG+ Metabolic Monitor
- Learn More
ExactaMix Pro Automated Compounder
- Learn More
Explore Baxter's Programs
Baxter’s commitment to advancing clinical nutrition extends beyond offering innovative products. Baxter also provides programs and tools to its clinicians, hospital partners and compounding pharmacies that improve care and pharmacy efficiency.
Education Customer Service
Indications for Use
Q-NRG+ Metabolic Monitor
Indications For Use: The Q-NRG+ portable Metabolic Monitors are indicated for the measurement of Resting Energy Expenditure (REE) for spontaneously breathing and ventilated patients, within the following populations:
• Spontaneously breathing subjects >15 kg (33 lb) when using a canopy.
• Spontaneously breathing subjects age >6 yrs and >10 kg (22 lb) when using a face mask.
• Ventilated subjects age >10 yrs and >10 kg (22 lb).
Q-NRG+ Portable Metabolic Monitors are intended to be used in professional healthcare facilities only (limited to ICUs for ventilated patients).
Warnings and Precautions: This device is not suitable for operating in presence of flammable anesthetic gases or gases other than O2, CO2, N2 and water vapor. The device is to be used by physicians or by trained personnel under the responsibility of a physician. The device is not intended as a continuous monitoring device for surveillance of vital physiological processes. The device measures clinical parameters used to aid diagnosis and it is intended only as an adjunct device in patient assessment. The device must be used in conjunction with other methods of assessing clinical signs and symptoms. No modification of this device is allowed. Residue and other contaminants in the breathing circuit pose a safety risk to the patient during testing procedures. Aspiration of contaminants can be potentially life-threatening.
Rx Only: For safe and proper use of the device, refer to the User Manual.
Rattanachaiwong S, et al. Indirect calorimetry as point of care testing. Clin Nutr 2018;38(6):2531-2544.
Zusman O, et al. Resting energy expenditure, calorie and protein consumption in critically ill patients: a retrospective cohort study. Critical Care 2016;20:367.
Zusman O, et al. Predictive equations versus measured energy expenditure by indirect calorimetry: A retrospective validation. ClinNutr. 2019;38(3):1206-1210.
McClave SA, et al. Guidelines for the Provision and Assessment of Nutrition Support Therapy in the Adult Critically Ill Patient: Society of Critical Care Medicine (SCCM) and American Society for Parenteral and Enteral Nutrition (A.S.P.E.N.). JPEN 2016;40:159-211.
Q-NRG+ Portable Metabolic Monitor Operator’s Manual, February 2021.
Oshima T, et al. In vitro validation of indirect calorimetry device developed for the ICALIC project against mass spectrometry. Clin Nutr 2019;32:50-55.
Oshima T, et al. Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group. Clin Nutr 2017;36:651-662.